Do you understand the problems that need to be avoided during the installation of Ready Board?

Publish Time: Author: Site Editor Visit: 351

Ready Board equipment is widely used in our life. Well installed Ready Board can prolong the service life of the equipment to a certain extent, but some problems need to be avoided if you want to install the Ready Board well. The following Ready Board factory will introduce the problems that need to be avoided in the installation of Ready Board.

 

Problem 1: the electric tools and surface equipment in the Ready Board (board) are not firm and flat, and the spacing does not meet the requirements.

 

The electric appliance and surface equipment in the Ready Board (board) are not firm and the spacing is not good, which will affect the application; Therefore, the surface of the equipment shall be firm, flat and regular, the spacing shall be uniform, the copper terminals shall not be loose, the opening and closing shall be flexible, and the parts shall be complete.

 

Problem 2: the laying of wires and pipelines in the Ready Board is too low.

 

The nozzle of the wire and pipeline laid in the Ready Board is too low, which is easy to cause ponding and sundries to enter the pipe and reduce the insulation strength of the conductor. The nozzle of the wire maintenance Pipe in the Ready Board should be 50 ~ 80mm higher than the bottom of the Ready Board. The pipelines shall be placed orderly, and the pipe orifice shall be trumpet shaped.

 

Problem 3: N and PE bus bars are not set in the Ready Board.

 

N and PE bus bars are not set in the Ready Board, which can not ensure the safe and stable operation of the line. In the lighting Ready Board (board), the busbar of zero line (N line) and maintenance ground line (PE line) shall be set respectively. The zero line and maintenance ground line shall be connected on the busbar without splicing, and shall be numbered.

 

The above are some problems that need to be avoided during the installation of the Ready Board equipment sorted out by the Ready Board factory. When installing the Ready Board equipment, it is necessary to avoid the unstable and uneven surface equipment, the low laying of wires and pipelines, and the non setting of N and PE bus bars in the Ready Board.

Recent News
Recommend Products
Food Paper Bags RFID Seal Cable Seal TWS Wireless Earbuds Sanitary Butterfly Valve Sanitary Ball Valve Insulated Piercing Connector Rigid Box Machine Rigid Box Machine Small Size Ball Valve Bolt Seal Flexible Copper Braided Wires 1PC BALL VALVE Sanitary Centrifugal Pump Acetate Optical Frames Sanitary Butterfly Valve 卫生离心泵 卫生离心泵 Anti Corrosion Pipe Supports Straw Paper Machine